Sign in
Register
Common Vision Blox, X64CLiPro, e2v Aviiva SC2
I have Common Vision Blox and a Dalsa Coreco X64 CL iPro framegrabber together with a color linescan camera e2v Aviiva SC2. I want to use an external triggersignal to synchronize the line frequency of the camera to the moving object. How do I configure that and are there special settings in Common Vision Blox?
Problem With ContourFinderX Control in Visual C++
I am using the ContourFinderX control in a Visual C++ application, and I want to filter out the found contours using the
OnOnQueryAcceptContour
Event as described in the documentation. However, if I assign
TRUE
or
FALSE
to the
*Accept
parameter, I get an unhandled exception when running the application. I have not changed the statements create by the Visual C++ class wizard. What is wrong?
When loading the Xcelera CVB Driver the debug window allways opens.
When loading the CVXceleraCLPX4.vin driver from any CVB application, the debug console windows allways opens and shows debug information. Even when the debug error log parameter in the .ini file is turned off. In addition the message: "INI-File not found -> Default values will be used." is shown in the error log.
FAQ (Cameras)
Absence of Features in the AVT Marlin series
One or more of the features described in the manual do not exist in the camera!
Allowable Cable Length for JAI M1
What distance can I cover with a standard cable, using the JAI M1?
Asynchronous Trigger Mode of the JAI M10 BX
What is the difference between H-reset and H-Non-Reset of triggering asynchronously the JAI M10 BX?
Asynchronous triggering of JAI M10 BX
How can I trigger the JAI M10 BX asynchronously?
AVT Camera Framerate is too low
I have a camera which can grab more than 25fps. But I only get 25fps.
Bayer Encoding Versus RGB Output
What's the advantage of a Camara with Bayer Encoding compared to a Camera with RGB output for Colour Images?
Black pixels on Sony DX-390P
The images from my Sony DX-390P in sync mode show on the side a 10 to 20 pixel wide black bar. My config-file might be O.K.. Whats wrong with my Camera?
Clouds of Black and White Pixels in PhotonFocus MV-D1024-28-LV-10 Images
I see clouds of black and white pixel in the images from a Photonfocus MV-D1024-28-LV-10 connected to a PCDigL. What can I do?
Connecting the JAI CV-S3200P/3300P to a Standard TV
Can the JAI CV-S3200P/S3300P be connected to a standard TV?
DALSA Piranha2 Sensor
Does the DALSA PIRANHA2 use the same sensor (IL/IT-P4) as the DALSA CL/CT-P4-6144W and -8129W cameras?
Definition Composite Video and S-Video
What does Composite Video mean?
Definition of Donpisha
What does Sony's Donpisha mode mean?
Definition of HD/VD
What does HD/VD mean in conjunction with analog cameras?
Definition of NTSC
What do the terms NTSC, EIA and RS-170 mean?
Definition of PAL
What do the terms PAL and CCIR mean?
Histogram for Color Linescan Camera in Sapera CamExpert
How can I get the color histogram of a color linescan camera like e.g. Akyla in the Sapera CamExpert?
Invisible JAI Camera Control Tool
I started the Camera Control Tool, I can see it in the taskbar, but I can't see the application on my desktop. Where is the application?
JAI A-Serie HyperTerminal Configuration
How does the HyperTerminal of WindowsNT/2000 have to be configured to access a JAI A-Series camera via the serial interface?
JAI A-Series Cameras Have a Different Pinout
Is there any difference in the pinout between the A-Series and the M-Series from JAI?
JAI CV-M4 CL Camera Link Standard Compatibility
The LEN and FEN signals of the JAI CV-M4 CL are active LOW. Is the camera not compatible to the Camera Link Standard which recommends a HIGH signal?
Live Acquisition Does Not Start With Pulnix TM9701 and Digital Frame Grabber
I have connected my Pulnix TM9701 camera to a PCDig/AM-Dig16/MTD frame grabber, and it displays images at the correct framerate, but all I get is the same image over and over again - even on an analog monitor/frame grabber. Why?
Lower Linerate Limitation with Dalsa Cameras
How do I run my Dalsa Spark/Spyder at a Linerate of less than 300 Hz?
Malfunction of DALSA SP-11/-12/-13/-14/-15/-16
My camera system worked well in the laboratory. After resettling it to the plant, there are black or white streaks occuring sporadically in the camera images. What's wrong?
Missing Camera Definition Files in the IFC/ITEX Camera Configurator
I have bought a camera from Stemmer (or one of its local distributors) that is supposed to run with the IFC/ITEX. However, when using the respective camera configurator I cannot find a camera definition file that seems appropriate for this camera. Why?
Multimedia Devices (USB Cams, Firewire IEEE1394, TV-Tuners) and CVB
Can I use CVB with my USB camera/IEEE1394 Firewire Camera/TV-Tuner card?
Pixel Effects With CMOS Sensors
In images taken with my CMOS sensor some pixels are brighter than they should be, some are darker. Why is this so?
Problems with JAI CV-M70 on PC-RGB in VScan Mode and Variable Shutter Times
I am using the JAI CV-M70 in variable scan (VScan) mode on a Coreco Image PC-RGB Frame Grabber. The cable is a 'COIM D44 M70FR' type from Stemmer Imaging. In principle this configuration is working, but there is a black bar at the top of each image, and this bar changes its height, when the shutter time is changes. How can I get rid of this bar?
Problems With Static IP Adress and Dalsa Genie
A static (persistent) IP adress has been assigned to a Genie camera. Now the camera cannot be found by the Dalsa Network Configuration Tool any more.
Running a JAI M10 in Seal 0 Mode on the PX610
How do I run a Seal 0 modified M10 in asynchronous reset mode on the PX610 correctly? If I simply connect everything and start acquiring images I only get a black image, with flashing images each time a trigger pulse is fired.
Switching between 240 V and 110 V
I have bought machine vision equipment in Europe, which is running on 240 V line voltage. Now I want to sell this into a country, where the line voltage is 110 V only. What do I have to take into account?
Switching Piranha2 Output Modes
What will be output, if I switch the Piranha2 from 10 Bit mode to 8 Bit mode?
Using the JAI CV-M70 on a Monitor
Is it possible to connect the JAI CV-M70 to a monitor instead of a Frame Grabber?
VRMagic AVC-1 and USB 1.x
Is it possible to use the analog to USB converter box VRmAVC-1 on a USB 1.x interface?
What Cable for Triggered Acquisition From A-Series Cameras
Can I use the COIM-D15-HIR cables, that I used with JAI M-Series Cameras to apply a software trigger to an A-Series camera?
Filters
Index
1
A
B
C
D
E
F
G
H
I
J
L
M
N
O
P
R
S
T
U
V
W
X
Keywords
.NET
10Bit-camera
240 V
A-Series
Acquisition Error
Allied Vision Technologies
Angle
ANSI C
Asynchronous Reset
AVI
Basic Dig I/O
Bayer
Board Level Library
Borland
buffer
Busmaster
C Builder
C++ Builder
Cable
Camera Configuration Files
Camera Configurator
Camera Control
Camera Link
CCIR
Clamping
Class
ClientToImage
CMOS
Color Image
COM Port
Composite
Control
Coordinate System
CopyImageArea
Createimageinsertlist
CreateImageMap
CreateMatrixTransformedImage
CreateMatrixTransformedImageEx
CreateSubImage
CVB System Information
CVCError Event
CVCFile.vin
cvDigIO.OCX
data valid signal
DataMatrix
DCOM98
Delphi
Demo Mode
Demos
Digital Frame Grabber
Digital I/O
DirectDraw
Display
Display OCX
DisplayClientToImage
DisplayImageToClient
Distance
Documentation
Dongle
Donpisha
DOTNET
Dual Display
DuplicateImage
DX-390P
EIA
Embedded PC
Error Console
Error Event
ExSync
Firewire
FPGA Applet
Frame Delay Readout
Frame Grabber
Frame Grabber Drivers
GetImageVPA
Gigabit Ethernet
Grabber OCX
H-Phase
Hardware Configuration Manager
Hardware Detection
HD
HD/VD out
high resolution cameras
Histogram
HyperTerminal
I/O Mapping
I/O Opto 88
IEEE 1394
IFC
Image
Image Coordinates
Image formats
Image Manager Training
Image Object
Image OCX
image scaling
ImageHistogram
ImageToClient
INI File
Installation
interlaced
IP adress
ITEX
large
Licensing
linear
Linescan Interface
Linescan OCX
LinLog
LVAL-synchronous
Magic Number
MapTo8Bit
Maximum Data Rate
medium
memory leak
Memory Mapping
Minos Classifier
Minos Teach
Minos Training Set
Mixing CVC and CVB
Monitor
Monochromatic Image
Monochrome Camera
More Than 8 Bits
MPEG
Multimedia
network settings
Node locked license
Non interlaced
NTSC
Origin
Overlay Plugins
PAL
PDF417
PFRemote
Pharmacode
pixeldepth
PLL
Porting from CVC to CVB
Power Consumption
Power Supply
PRI
Printing
progressive scan
Reference Counter
ReleaseImage
RemoveAllOverlayObjects
RemoveAllOverlays
RGB
RGB_PLANAR
Rotation
RS-170
RS232
S-Video
SaveWindowToBitmap
Saving Images
scaling
SCART
Screen Coordinates
Seal 0
SECAM
Separate Sync
Sequence
serial port
Signal Range
small
Snap method
Software Trigger
strobe
Sync On Green
Synchronization
Timeout
Tool
Tools
trigger
trigger inputs
Trigger, Software
TV
Updating
USB
Variable Scan
VD
Video Signal
VIN Driver
Vision Blox
Visual Basic
Visual C++
VPAT
VScan
WaitPingPong
Windows 2000
Windows 95
Windows 98
Windows NT
Windows XP
X-Tal Mode
Y/C
Sections
Cameras
Cabling
Acquisition
Software
Systems
Accessories
Suppliers
AVT
Common Vision Blox
JAI
Microsoft
Sony
STEMMER IMAGING
Teledyne DALSA
Products
AVT Oscar
Common Vision Blox
CVB Barcode
CVB Color
CVB Edge
CVB Foundation Package (until CVB version 10.2, Win 32 only)
CVB Image Manager
CVB Manto
CVB Minos
CVB Movie
CVB PrintQual
CVB ShapeFinder
DALSA PC2-Vision / PC2-Vision Express
DALSA Piranha2
DALSA SAPERA LT
DALSA X64 Xcelera-CL
DALSA X64-AN Quad
DALSA X64-CL iPRO
DALSA X64-LVDS
JAI A1
JAI A11
JAI A50
JAI A60
JAI M10 SX
JAI M2
JAI M4+
JAI M50
JAI M7+
JAI M77
JAI TM-1405
JAI TM-6740
» Home
» FAQ
» Cameras
Expertise
Expertise
Difference
Benefits
Flexibility
Licensing
Elements
Elements
Fundamentals
Image Manager
Foundation Package
Tools
News
News
Events
Global Presence
Global Presence
Manufacturer
Distributors
Experience
Experience
Applications
Printed Articles
Support
Support
Download
Order DVD
Training
FAQ
Phone:
+49 89 80902-0
Fax:
+49 89 80902-116
info@stemmer-imaging.de
Legal
Disclaimer
Privacy Statement
Callback Service
Contact us
Order DVD